| 额定值 |
| 3 相交流系统 | Up to 440V, +10%, -15% for Cat. No. QC1_DP |
| | Up to 500 V, +10%, -15% for Cat. No. QC2_DP |
| 频率范围 (50-60Hz) | Control range of 45 - 65 Hz |
| 控制规范 |
| 控制系统 | 带微处理器的数字系统 |
| | 带电压和电流递增限制的启动斜坡 |
| 初始电压(脚踏板) | 30%-95% Un |
| 起动扭矩 | 10% - 90% Mdirect start |
| 脚启动 | 95% Un (90% Mdir.start), adjustable 0 to 999ms. |
| 电动机电流 (lm) | 0.4 to 1.2 Ir (rated ASTAT current) |
| 加速斜坡时间 | 1 to 99s (types: standard or linear ramp up) |
| 节能 | 输出电压降低符合功率因数 |
| 超越 | 固定输出电压永久性与电源电压相等 |
| 旁路 | 旁路接触器直接控制 |
| 减速斜坡时间 | 1 至 120s(二次斜坡中为 1s 至 99s) |
| | 模式:滑行停机、软停机 |
| | 泵控制或线性斜降 |
| 直流制动 | 0 to 99s ; 0.5 to 2.5 lr |
| 低速 | Forward: 7% or 14% nominal speed |
| | Reverse: 20% nominal speed |
| 重试 | 0 to 4 attemps, and 1to 99 sec. retry time |
| 监控 | 电动机电流、线路电压、功率、功率因数以及消逝时间 |
| 运行 |
| 外部控制 | 启动 — 停机 |
| 加速阶段 | 可调时间/泵控制 |
| 永久阶段 | 节能/超越 |
| 停机阶段 | 切断电源/斜坡/直流制动/泵控制 |
| 输入/输出 |
| 输入 | 4 数字光耦合 |
| | 2 个固定(启动、停机),2 个可编程(I3、I4) |
| | 1 个模拟 0-5VDC 用于测速发电机输入反馈 |
| | 2 个输入用于电动机热敏电阻 |
| 输出 | 3 个可编程继电器(1r 转换、2r、3r) |
| | 1 个模拟 0-10V DC 输出用于电流计量 |
| 通信 |
| | 标准型为 ASCII 和 Modbus RTU |
| | Profibus DP 和 DeviceNet 作为可选外部模块 |
| 保护 |
| 电流限制 | 在1xln 到 7xln 内可调 |
| 过载 | Class IEC 10 and 20 (selectable) |
| | Class NEMA 10, 20 and 30 (selectable) |
| | OFF desactivado |
| 过载跳闸后冷却时间 | 300 s for reset |
| 输入阶段损失 | Trip at 3 s |
| 晶闸管短路 | Trip at 200 ms |
| 散热片过热 | Trip at 200 ms |
| 电动机热敏电阻 | Trip at 200 ms |
| 输出阶段损失 | Trip at 3s |
| 转子失速 | Trip at 200 ms |
| 电源频率误差 | Si f < 45Hz of > 65 Hz |
| 过电流 | 100 to 150% ln; trip time adjustable from 0 to 99s |
| 欠电流 | 0 to 99% ln; trip time adjustable from 0 to 99s |
| 过电压 | 100% to 130% Un; trip time adjustable from 0 to 99s |
| Undervoltage | 0 to 50% Un; trip time adjustable from 0 to 99s |
| 误差 (CPU) | 60ms |
| 内存 | 4 former errors |
| 启动时间长 | 2 x ta ( ta= acceleration ramp time) |
| 低速时间长 | 120s |
| 环境条件 |
| 温度 | 0 to +55° C |
| | (derate output current by 1.5% /°C above 40°C) |
| 相对湿度 | 95% without condensation |
| 最高海拔 | 3000 m |
| 安装位置 | (derate output current by 1%/100m above 1000m) |
| 防护等级 | 垂直 |
| IP 00, (UL open) |
| 标准 |
| CE, cUL, UL | CE conforming IEC 947-4-2 |
| | UL, cUL conforming UL 508 |
| 传导发射和辐射发射 | Conforming IEC 947-4-2, Class A |
| 静电放电 | Conforming IEC 1000-4-2, level 3 |
| 无线电干扰 | Conforming IEC 1000-4-6, level 3 and |
| | to IEC 1000-4-3, level 3 |
| 抗快速瞬变 | Conforming IEC 1000-4-4, level 3 |
| 抗浪涌电压 | Conforming IEC 1000-4-5, level 3 |